Skip to Main Content
DC/AC Power Converter Unit, 125 kVA intelligent air-cooled bidirectional power conversion unit

DC/AC POWER CONVERTER UNIT

DC/AC power conversion unit125 kVA · 1000 V intelligent air-cooled bidirectional converter

Built for commercial, industrial, and medium-to-large energy storage systems, combining high-efficiency three-level conversion technology andIntelligent forced-air cooling system, with peak efficiency up to 98.5%, with no derating at full load in a 45°C environment, and with IP66 protectionand full grid frequency and voltage regulation capability.

IECCEISO 9001:2015IATF 16949:2016TÜV RheinlandRoHS

Key Features

High-efficiency Output

Uses advanced three-level technology, with conversion efficiency up to 98.5%. Intelligent air cooling, full load without derating below 45°C. A wide DC voltage range, supporting full-power operation at 1000 V.

Smart maintenance and weather resistance

A modular body for simple, fast maintenance. The complete unit is rated IP66 against dust and water, and C5 corrosion protection can be selected for high salt-spray coastal sites.

Flexible configuration

Operates in full four-quadrant bidirectional power conversion and is compatible with high-voltage battery systems, to lower total system cost; integrates battery charge and discharge management and black start (Black Start).

Grid ancillary services and compliance

Complies with IEC 62477, IEC 62109, and grid-connection codes. Provides a fast response in active and reactive power, and supports L/HVRT, VSG, FRT, soft start and stop, and power-factor control.

Specifications|DC/AC POWER CONVERTER UNIT

ETICA
General Specifications
Dimensions820 × 310 × 1,019 mm
Weight105 kg
Protection RatingIP66
Operating Temperature-30°C to +60°C (>45°C derating)
Operating Humidity0%–100%
Cooling MethodIntelligent air cooling (Intelligent Air Cooling)
Altitude≤ 4,000 m (>4,000 m derating)
Performance
DC voltage range600–1,000 V
Maximum DC power137.5 kW
Rated AC power125 kVA
AC Voltage400 V
Maximum conversion efficiency98.5%
Safety Protection
Protection RatingIP66
Surge ProtectionDC Type II / AC Type III
Safety ProtectionReverse-polarity protection, short-circuit protection, and leakage-current protection
System MonitoringGrid monitoring, ground-fault monitoring, and insulation monitoring
Anti-islanding ProtectionFrequency shift (Frequency Shift)

Please contact ETICA for a project estimate. Final figures depend on system design, installation site, and how the system is used.